Product Quality Documentation for MOD14A2, C5



Collection C5

ParameterName: All
BeginDateTimeEndDateTime ScienceQualityFlagScienceQualityFlagExplanation CommentsMaturity
2000 055
(02/24/00)
2000 112
(04/21/00)
Suspect Product is noticably degraded due to poor quality of data acquired with mid-infrared channels.   Validated stage 3
2000 113
(04/22/00)
2000 120
(04/29/00)
Suspect MODIS nadir aperture door was closed part time on 2000116 and 2000119, all time on 2000117 and 2000118.   Validated stage 3
2000 121
(04/30/00)
2000 216
(08/03/00)
Suspect Product is noticably degraded due to poor quality of data acquired with mid-infrared channels.   Validated stage 3
2000 217
(08/04/00)
2000 232
(08/19/00)
Suspect MODIS-L1B data was not available for days 2000219 - 2000230 due to L1B formatter anamoly.   Validated stage 3
2000 233
(08/20/00)
2000 312
(11/07/00)
Suspect Product is noticably degraded due to poor quality of data acquired with mid-infrared channels.   Validated stage 3
2000 313
(11/08/00)
2003 344
(12/10/03)
Inferred Passed     Validated stage 3
2003 345
(12/11/03)
2003 360
(12/26/03)
Suspect MODIS-Terra went into safe hold on day 2003350 and came back on day 2003359. No MODIS L1B data were available for these days. The day 2003359 had unreliable calibration.   Validated stage 3
2003 361
(12/27/03)
2006 232
(08/20/06)
Inferred Passed     Validated stage 3
2006 233
(08/21/06)
2006 240
(08/28/06)
Suspect The Space View Door (SVD) and Nadir Aperture Door (NAD) on the EOS Terra MODIS instrument were closed part time on 2006234 and 2006235.   Validated stage 3
2006 241
(08/29/06)
. . . Inferred Passed     Validated stage 3


Updated on 08-30-2013